SerMimar® Studio · Est. 2008 · ISO 19650 BIM & Architectural Engineering
SERMIMAR EST. 2008
LOD 350 / 400 5,000 – 75,000 m²

3D BIM Clash Detection & Engineered Resolution: Tolerances, Workflow & Fees

Rule-based Navisworks & Solibri spatial auditing plus active engineering redesign to deliver signed zero-clash construction models.

3D BIM clash detection audit highlighting resolved structural beam and HVAC duct intersections
Arch × Struct × HVAC × Plumbing/Fire × Electrical 2 – 4 Weeks (or Weekly Sprint)
Engineering Specification & Fee Snapshot
ISO 19650 · Navisworks Manage · Solibri · BCF 2.1/3.0
BIM Detail Level LOD 350 / 400
Reference Scale 5,000 – 75,000 m²
Delivery Schedule 2 – 4 Weeks (or Weekly Sprint)
Indicative Studio Fee $9,500 – $24,000 (for 15,000 m² audit & resolution)
Ref. Construction CAPEX Saves 4% – 8% of Total Construction CAPEX
Native File Outputs .NWD / .NWF · Solibri .SMC · BCF Issue Logs · Audit PDF
A B C GRID A-01 / LOD 400 FEDERATED SECTION ARCHITECTURAL ENVELOPE (U ≤ 0.24 W/m²K) STRUCTURAL FRAME & SEISMIC NODE (EC8 / TBDY) MEP CORRIDOR — ZERO CLASH ZONE (±3 mm) 5D BoQ & CNC / SHOP DRAWING OUTPUT SERMIMAR STUDIO · ISO 19650 · IFC4 / RVT / DWG

Technical Parameters & Tolerance Matrix

Engineering Parameter Specification Benchmark
Target BIM Level & Governing Norm LOD 350 / 400 · ISO 19650 · Navisworks Manage · Solibri · BCF 2.1/3.0
Reference Gross Scale 5,000 – 75,000 m²
Coordinated Disciplines Arch × Struct × HVAC × Plumbing/Fire × Electrical
Milestone Delivery Schedule 2 – 4 Weeks (or Weekly Sprint)
Indicative Studio Fee Band $9,500 – $24,000 (for 15,000 m² audit & resolution)
Native File Deliverables .NWD / .NWF · Solibri .SMC · BCF Issue Logs · Audit PDF
SEC 01

Project & Engineering Scope Overview

Raw clash reports containing 15,000 ungrouped intersections paralyze project teams instead of helping them. SerMimar performs intelligent rule-based clash grouping, priority ranking, and engineered rerouting—delivering actionable BCF solutions rather than raw error dumps.

Engineered to LOD 350 / 400 precision across a reference benchmark of 5,000 – 75,000 m² under ISO 19650 · Navisworks Manage · Solibri · BCF 2.1/3.0, this canonical specification unifies spatial design, multidisciplinary clash resolution, and 5D cost certainty prior to site mobilization.

SEC 02

Architectural Layout, Structural Grid & Spatial Zoning

Structural Grid & Modular Alignment: Zone-by-zone and level-by-level clash partitioning prioritizing high-consequence subterranean foundations, risers, and podium transfer slabs.

Primary column grids, facade mullion subdivisions, and subterranean parking geometry are locked onto a unified datum—eliminating non-standard off-cuts and costly site framing adjustments.

SEC 03

Functional Area Program & Net-to-Gross Floor Plate Optimization

Spatial Program & Net-to-Gross Efficiency: Ceiling void pinch-point heatmaps identifying zones where combined structural depth and MEP crossovers threaten architectural clear height.

Live parametric Revit area schedules track net usable/leasable floor area against vertical cores, MEP plantrooms, and envelope wall thickness at every design iteration.

SEC 04

Circulation Cores, Logistics Access & Life-Safety Egress

Vertical Cores, Logistics & Life-Safety Egress: Headroom clearance rules (≥2,100 mm ramps/parking, ≥2,400 mm corridors) and fire-door swing envelope verification.

Travel distances, pressurized stair cores, ADA/accessible routing, and heavy service/loading dock swept-path geometry are validated against NFPA, EN, and local building regulations.

SEC 05

Site Utilities, Stormwater Drainage & Wet-Shaft Engineering

Subsurface Utilities, Drainage & Wet Shafts: Gravity drainage slope protection rules ensuring pressurized pipes and cable trays route around fixed-invert sewer and rainwater mains.

Gravity stormwater and foul drainage stacks are modeled with true 1.5%–2.0% invert slopes, locking structural beam web penetrations and acoustic riser sleeves before rebar detailing.

SEC 06

Plumbing, Fire Suppression (NFPA / EN) & Hydronic Piping BIM

Domestic Plumbing, NFPA/EN Sprinkler & Hydronics: Zero-tolerance hard clash checks (±2 mm) on high-pressure fire mains, seismic bracing sway zones, and riser manifold clusters.

Wet/dry sprinkler grids, fire hose cabinets, booster pump skids, and hydronic manifolds are spatially coordinated above ceiling plenums without compromising architectural clear heights.

SEC 07

HVAC Climatic Routing, Acoustic Control & Zero-Clash MEP

HVAC Routing, Acoustics & Zero-Clash Verification: Soft clearance buffers (25–50 mm thermal insulation + 450–600 mm filter/coil service access) around VAV boxes, dampers, and AHUs.

Automated Navisworks and Solibri rule-sets enforce ±3 mm hard-clash tolerances and 25–50 mm insulation/maintenance clearance zones, closing 100% of BCF issues prior to tender issue.

SEC 08

Structural Steel / RC Framing & Seismic Performance Analysis

Structural Framing & Seismic Engineering: Strict protection of post-tensioned tendons, column shear capitals, and steel moment connection gussets from unauthorized coring.

Inter-story seismic drift ratios, ductile steel moment/braced connections, foundation punching shear, and secondary facade subframes are signed off by our senior structural engineering partners.

SEC 09

Facade Envelope, Roof Assembly & Hygrothermal U-Value Detailing

Building Envelope & Hygrothermal Physics: Curtain-wall mullion anchor brackets checked against perimeter edge beams, raised floor pedestals, and perimeter trench heaters.

2D/3D thermal-bridge condensation risk is audited per EN ISO 6946, pairing Class A1 mineral-wool insulation, vapor-permeable membranes, and slotted seismic facade brackets at 1:5 shop detail scale.

SEC 10

Georeferenced Site Plan & ISO 19650 Common Data Environment (CDE)

Georeferenced Masterplan & ISO 19650 CDE: Bi-directional BCF 3.0 synchronization with BIMcollab, ACC, or Revizto—assigning every clash cluster an owner, root solution, and deadline.

All discipline models share true survey coordinates (UTM / National Grid) and progress through ISO 19650 WIP → Shared → Published gates inside the Common Data Environment.

SEC 11

BIM & Construction Document Deliverables (.RVT / .IFC4 / .NWD / .DWG)

Native BIM & Construction Documentation Package: Search-sets configured .NWF/.NWD files, Solibri ruleset reports, grouped BCF packages, and executive Zero-Clash Sign-Off Certificate.

Clients receive unlocked native .NWD / .NWF · Solibri .SMC · BCF Issue Logs · Audit PDF source files, plotted PDF/DWG construction sets, and signed zero-clash audit certificates.

SEC 12

5D Quantity Take-Off (BoQ), Studio Fee Band & Cost Benchmarks

5D Quantity Take-Off (BoQ) & Indicative Studio Fee: The indicative engineering & BIM fee band for this reference scope is $9,500 – $24,000 (for 15,000 m² audit & resolution) (with indicative construction CAPEX benchmark at Saves 4% – 8% of Total Construction CAPEX). Industry benchmarks prove each major MEP/structural clash resolved digitally saves $1,500–$8,500 in site demolition, core-drilling, and schedule delay.

SEC 13

DfMA Prefabrication, 40HC Export Packaging & Execution Pathways

DfMA Prefabrication & Export Execution Pathways: Validates prefabricated MEP module transport envelopes and crane hook clearances prior to factory assembly.

Clients may tender the open BIM package to any local contractor or leverage our integrated group factories (SerBuild steel structures, SerMimar İskele EN 12810 scaffolding, SerMimar Şömine hearths, and SerSourcing 40HC consolidation).

SEC 14

International Building Codes, Green Certification & Grant Readiness

International Codes, Sustainability & Compliance: Aligned with ISO 19650-2 coordination gates, UK Government Soft Landings, and FIDIC/NEC4 contractor technical risk mitigation.

Structured directly for LEED / BREEAM / RE2020 energy modeling, UK Building Safety Act Golden Thread compliance, Eurocode National Annexes, and institutional lender due diligence.

INTERACTIVE ENGINEERING & FEE ENGINE

BIM, Masterplan & Facade Scope Calculator

UK ISO 19650 · RIBA Stages 2–5 · Part B/L
m²
500 m² 10,000 m² 25,000 m² 60,000+ m²
Estimated Studio Engineering Fee Band $98,500 – $127,600 (€90,600 – €117,400)
Estimated Engineering Load 1550–1980 man-hours
Milestone Delivery Schedule 10–16 weeks
Est. BIM Views & CD Sheets ~152 sheets / models
Indicative Construction CAPEX Ref. $18,000,000 – $27,750,000
Included Native Deliverables
  • Federated .RVT / .NWD
  • BCF Clash-Free Audit Report
  • 5D Itemized BoQ (.XLSX)
  • Full CD .DWG Set
Request Detailed Engineering & Cost Study via WhatsApp
CROSS-DISCIPLINE ARCHITECTURE

Explore complementary BIM levels, building typologies, and facade/DfMA specifications.

TECHNICAL & COMMERCIAL Q&A

Frequently Asked Engineering & Commercial Questions

Direct technical answers on deliverables, ISO 19650 workflows, revisions, and fee structures.

Do you just send a Navisworks clash report, or do you actually fix the clashes inside Revit?
Both options are available: we act as an independent third-party BIM auditor issuing prioritized BCF solutions, OR our multidisciplinary engineers directly modify the Revit models to deliver a 100% clash-free package.
How do you turn 10,000 raw clashes into manageable engineering tasks?
We cluster geometric intersections by root cause—for example, a single duct run intersecting 40 ceiling joists is grouped as 1 actionable routing issue rather than 40 noisy alerts.
What discipline hierarchy governs who moves when two systems collide?
We follow proven physics hierarchy: 1) Primary Seismic Structure & PT Tendons, 2) Architecture & Facade Envelope, 3) Gravity Sloped Drainage, 4) Large-Section HVAC Ducts, 5) Pressurized Piping & Cable Trays.
Can you audit IFC models exported from Archicad, Allplan, Tekla, and MagiCAD?
Yes. Using OpenBIM IFC2x3 and IFC4 workflows in Solibri and Navisworks, we seamlessly federate models authored across heterogeneous software platforms.
How fast can you run an emergency pre-tender BIM clash audit?
An executive pre-tender clash & constructability audit for a 10,000–20,000 m² building is delivered within 5 to 7 business days.
SECTION 16 · DIRECT ENGINEERING PROPOSAL & WHATSAPP DESK

Request a Scoped BIM, Masterplan or Facade Engineering Proposal

Share your site parcel, CAD sketches, or point-cloud survey directly with our founding architects and civil engineers. Receive an itemized LOD deliverables matrix and fixed milestone schedule within 24 hours.