SerMimar® Studio · Est. 2008 · ISO 19650 BIM & Architectural Engineering
SERMIMAR EST. 2008
LOD 350 5,000 – 35,000 m²

LOD 350 4-Discipline Federated BIM Coordination: Interfaces, Clearances & Fees

Construction-ready RIBA Stage 4 federated coordination modeling exact structural connections, MEP hangers, slab penetrations, and zero-clash ceiling plenums.

LOD 350 4-discipline federated BIM model coordinating structural beams, HVAC ducts, cable trays, and curtain wall anchors
Architectural + Structural + Mechanical + Electrical 4 – 6 Weeks
Engineering Specification & Fee Snapshot
ISO 19650-2 · RIBA Stage 4 · BIM Forum LOD 350
BIM Detail Level LOD 350
Reference Scale 5,000 – 35,000 m²
Delivery Schedule 4 – 6 Weeks
Indicative Studio Fee $26,500 – $48,000 (for 10,000 m² ref.)
Ref. Construction CAPEX $12.0M – $18.5M Construction Ref.
Native File Outputs Federated .RVT · .IFC4 · .NWD · BCF Audit · .DWG
A B C GRID A-01 / LOD 400 FEDERATED SECTION ARCHITECTURAL ENVELOPE (U ≤ 0.24 W/m²K) STRUCTURAL FRAME & SEISMIC NODE (EC8 / TBDY) MEP CORRIDOR — ZERO CLASH ZONE (±3 mm) 5D BoQ & CNC / SHOP DRAWING OUTPUT SERMIMAR STUDIO · ISO 19650 · IFC4 / RVT / DWG

Technical Parameters & Tolerance Matrix

Engineering Parameter Specification Benchmark
Target BIM Level & Governing Norm LOD 350 · ISO 19650-2 · RIBA Stage 4 · BIM Forum LOD 350
Reference Gross Scale 5,000 – 35,000 m²
Coordinated Disciplines Architectural + Structural + Mechanical + Electrical
Milestone Delivery Schedule 4 – 6 Weeks
Indicative Studio Fee Band $26,500 – $48,000 (for 10,000 m² ref.)
Native File Deliverables Federated .RVT · .IFC4 · .NWD · BCF Audit · .DWG
SEC 01

Project & Engineering Scope Overview

LOD 350 Multidisciplinary BIM Coordination resolves the critical physical interfaces between all four building systems—modeling secondary steel supports, MEP trapeze hangers, fire-damper access zones, and builder’s work openings (BWIC) before tender.

Engineered to LOD 350 precision across a reference benchmark of 5,000 – 35,000 m² under ISO 19650-2 · RIBA Stage 4 · BIM Forum LOD 350, this canonical specification unifies spatial design, multidisciplinary clash resolution, and 5D cost certainty prior to site mobilization.

SEC 02

Architectural Layout, Structural Grid & Spatial Zoning

Structural Grid & Modular Alignment: Coordinated structural and ceiling grid alignment locking diffuser, sprinkler head, luminaire, and curtain-wall mullion centerlines.

Primary column grids, facade mullion subdivisions, and subterranean parking geometry are locked onto a unified datum—eliminating non-standard off-cuts and costly site framing adjustments.

SEC 03

Functional Area Program & Net-to-Gross Floor Plate Optimization

Spatial Program & Net-to-Gross Efficiency: Verified net clear ceiling heights (e.g., ≥2,750 mm offices, ≥3,200 mm lobbies) preserved after full multi-tier MEP duct/tray stacking.

Live parametric Revit area schedules track net usable/leasable floor area against vertical cores, MEP plantrooms, and envelope wall thickness at every design iteration.

SEC 04

Circulation Cores, Logistics Access & Life-Safety Egress

Vertical Cores, Logistics & Life-Safety Egress: Corridor plenum cross-sections engineered at 1:20 scale with dedicated vertical zones for supply/return air, cable containment, and fire mains.

Travel distances, pressurized stair cores, ADA/accessible routing, and heavy service/loading dock swept-path geometry are validated against NFPA, EN, and local building regulations.

SEC 05

Site Utilities, Stormwater Drainage & Wet-Shaft Engineering

Subsurface Utilities, Drainage & Wet Shafts: 100% locked Builder’s Work in Connection (BWIC) structural wall/slab penetration drawings with fire-collar and acoustic sleeve schedules.

Gravity stormwater and foul drainage stacks are modeled with true 1.5%–2.0% invert slopes, locking structural beam web penetrations and acoustic riser sleeves before rebar detailing.

SEC 06

Plumbing, Fire Suppression (NFPA / EN) & Hydronic Piping BIM

Domestic Plumbing, NFPA/EN Sprinkler & Hydronics: Sloped cast-iron/HDPE drainage stacks, condensate traps, and NFPA 13 sprinkler branch lines coordinated around structural gussets.

Wet/dry sprinkler grids, fire hose cabinets, booster pump skids, and hydronic manifolds are spatially coordinated above ceiling plenums without compromising architectural clear heights.

SEC 07

HVAC Climatic Routing, Acoustic Control & Zero-Clash MEP

HVAC Routing, Acoustics & Zero-Clash Verification: Full duct insulation thickness, valve actuator clearance, and VAV/FCU filter pull-out maintenance envelopes verified clash-free in Navisworks.

Automated Navisworks and Solibri rule-sets enforce ±3 mm hard-clash tolerances and 25–50 mm insulation/maintenance clearance zones, closing 100% of BCF issues prior to tender issue.

SEC 08

Structural Steel / RC Framing & Seismic Performance Analysis

Structural Framing & Seismic Engineering: Baseplates, shear tabs, secondary facade support steel, lintels, and rebar congestion zones coordinated against embed plates.

Inter-story seismic drift ratios, ductile steel moment/braced connections, foundation punching shear, and secondary facade subframes are signed off by our senior structural engineering partners.

SEC 09

Facade Envelope, Roof Assembly & Hygrothermal U-Value Detailing

Building Envelope & Hygrothermal Physics: Slab-edge curtain-wall anchor embeds, perimeter fire-stop mineral wool safing, and parapet waterproofing upstands resolved in 3D.

2D/3D thermal-bridge condensation risk is audited per EN ISO 6946, pairing Class A1 mineral-wool insulation, vapor-permeable membranes, and slotted seismic facade brackets at 1:5 shop detail scale.

SEC 10

Georeferenced Site Plan & ISO 19650 Common Data Environment (CDE)

Georeferenced Masterplan & ISO 19650 CDE: Weekly ISO 19650 federated model publication (.NWD / IFC4) with tracked BCF issue resolution logs across all 4 disciplines.

All discipline models share true survey coordinates (UTM / National Grid) and progress through ISO 19650 WIP → Shared → Published gates inside the Common Data Environment.

SEC 11

BIM & Construction Document Deliverables (.RVT / .IFC4 / .NWD / .DWG)

Native BIM & Construction Documentation Package: 4 native Revit discipline models, federated Navisworks (.NWD), zero-clash BCF audit certificate, BWIC penetration set, and 1:50 / 1:20 CDs.

Clients receive unlocked native Federated .RVT · .IFC4 · .NWD · BCF Audit · .DWG source files, plotted PDF/DWG construction sets, and signed zero-clash audit certificates.

SEC 12

5D Quantity Take-Off (BoQ), Studio Fee Band & Cost Benchmarks

5D Quantity Take-Off (BoQ) & Indicative Studio Fee: The indicative engineering & BIM fee band for this reference scope is $26,500 – $48,000 (for 10,000 m² ref.) (with indicative construction CAPEX benchmark at $12.0M – $18.5M Construction Ref.). Eliminates 92–98% of on-site MEP/structural RFI change orders, typically saving 4% to 7% of total construction CAPEX.

SEC 13

DfMA Prefabrication, 40HC Export Packaging & Execution Pathways

DfMA Prefabrication & Export Execution Pathways: Enables pre-corrugated slab sleeves and modular pre-assembled corridor MEP racks ready for fast-track installation.

Clients may tender the open BIM package to any local contractor or leverage our integrated group factories (SerBuild steel structures, SerMimar İskele EN 12810 scaffolding, SerMimar Şömine hearths, and SerSourcing 40HC consolidation).

SEC 14

International Building Codes, Green Certification & Grant Readiness

International Codes, Sustainability & Compliance: Compliant with UK ISO 19650 RIBA Stage 4 Technical Design, Dubai Municipality LOD 350 Mandate, and HOAI LP 5.

Structured directly for LEED / BREEAM / RE2020 energy modeling, UK Building Safety Act Golden Thread compliance, Eurocode National Annexes, and institutional lender due diligence.

INTERACTIVE ENGINEERING & FEE ENGINE

BIM, Masterplan & Facade Scope Calculator

UK ISO 19650 · RIBA Stages 2–5 · Part B/L
m²
500 m² 10,000 m² 25,000 m² 60,000+ m²
Estimated Studio Engineering Fee Band $74,600 – $96,600 (€68,600 – €88,900)
Estimated Engineering Load 1170–1495 man-hours
Milestone Delivery Schedule 8–12 weeks
Est. BIM Views & CD Sheets ~101 sheets / models
Indicative Construction CAPEX Ref. $12,000,000 – $18,500,000
Included Native Deliverables
  • Federated .RVT / .NWD
  • BCF Clash-Free Audit Report
  • 5D Itemized BoQ (.XLSX)
  • Full CD .DWG Set
Request Detailed Engineering & Cost Study via WhatsApp
CROSS-DISCIPLINE ARCHITECTURE

Explore complementary BIM levels, building typologies, and facade/DfMA specifications.

TECHNICAL & COMMERCIAL Q&A

Frequently Asked Engineering & Commercial Questions

Direct technical answers on deliverables, ISO 19650 workflows, revisions, and fee structures.

What is the core difference between LOD 300 and LOD 350 in real site construction?
LOD 300 shows where a duct or facade panel sits; LOD 350 models the actual steel hanger brackets, flange clearances, insulation thickness, slab sleeves, and facade anchor embeds that physically connect disciplines together.
Do you deliver Builder’s Work in Connection (BWIC) opening drawings from LOD 350?
Yes. Every approved MEP penetration through shear walls, beams, and slabs is automatically tagged with dimensions, invert elevations, and sleeve IDs on dedicated BWIC sheets prior to concrete pour.
How do weekly coordination meetings run with international project teams?
Each week we publish an updated federated model and HTML/BCF clash dashboard, hosting a focused 45-minute live Navisworks walkthrough to sign off critical structural or architectural pinch-points.
Can you coordinate third-party structural or MEP consultant models alongside our architectural model?
Yes. We either author all 4 disciplines in-house or act as Lead BIM Coordinator federating and resolving clashes across your external consultants’ Revit/IFC models.
What is the typical delivery timeline for a 10,000 m² 4-discipline LOD 350 project?
A 10,000 m² commercial, hospitality, or residential block typically completes full 4-discipline LOD 350 modeling and zero-clash sign-off in 4 to 6 weeks.
SECTION 16 · DIRECT ENGINEERING PROPOSAL & WHATSAPP DESK

Request a Scoped BIM, Masterplan or Facade Engineering Proposal

Share your site parcel, CAD sketches, or point-cloud survey directly with our founding architects and civil engineers. Receive an itemized LOD deliverables matrix and fixed milestone schedule within 24 hours.