SerMimar® Studio · Est. 2008 · ISO 19650 BIM & Architectural Engineering
SERMIMAR EST. 2008
LOD 350 / 400 Steel 2,000 – 50,000 m²

Structural Steel & Precast BIM Detailing: Connections, CNC Files & Fee Guide

Engineer-governed Tekla & Revit structural detailing for clear-span industrial halls, seismic steel frames, space trusses, and precast concrete structures.

3D structural steel BIM detailing showing bolted moment end-plates, portal frame haunches, and bracing gussets
Hot-Rolled Steel + Cold-Formed Purlins + Precast / Anchor Bolts 3 – 5 Weeks
Engineering Specification & Fee Snapshot
Eurocode 3 & 8 · AISC 360/341 · EN 1090-2 · TBDY 2018
BIM Detail Level LOD 350 / 400 Steel
Reference Scale 2,000 – 50,000 m²
Delivery Schedule 3 – 5 Weeks
Indicative Studio Fee $14,000 – $32,000 (for 10,000 m² / ~450–600t steel ref.)
Ref. Construction CAPEX Zero Field-Torch Cutting · ±0.5% Steel Tonnage Precision
Native File Outputs Tekla / Revit .IFC4 · .NC1 (DSTV) · .DXF · GA & Assembly .DWG
A B C GRID A-01 / LOD 400 FEDERATED SECTION ARCHITECTURAL ENVELOPE (U ≤ 0.24 W/m²K) STRUCTURAL FRAME & SEISMIC NODE (EC8 / TBDY) MEP CORRIDOR — ZERO CLASH ZONE (±3 mm) 5D BoQ & CNC / SHOP DRAWING OUTPUT SERMIMAR STUDIO · ISO 19650 · IFC4 / RVT / DWG

Technical Parameters & Tolerance Matrix

Engineering Parameter Specification Benchmark
Target BIM Level & Governing Norm LOD 350 / 400 Steel · Eurocode 3 & 8 · AISC 360/341 · EN 1090-2 · TBDY 2018
Reference Gross Scale 2,000 – 50,000 m²
Coordinated Disciplines Hot-Rolled Steel + Cold-Formed Purlins + Precast / Anchor Bolts
Milestone Delivery Schedule 3 – 5 Weeks
Indicative Studio Fee Band $14,000 – $32,000 (for 10,000 m² / ~450–600t steel ref.)
Native File Deliverables Tekla / Revit .IFC4 · .NC1 (DSTV) · .DXF · GA & Assembly .DWG
SEC 01

Project & Engineering Scope Overview

Structural steel profitability and seismic safety live or die at the connection node. Supervised by Civil Engineer Co-Founder Celalettin YAĞMAHAN, SerMimar delivers Eurocode 3/8 and AISC compliant 3D connection design and Tekla/Revit LOD 400 fabrication packages that bolt together cleanly on site.

Engineered to LOD 350 / 400 Steel precision across a reference benchmark of 2,000 – 50,000 m² under Eurocode 3 & 8 · AISC 360/341 · EN 1090-2 · TBDY 2018, this canonical specification unifies spatial design, multidisciplinary clash resolution, and 5D cost certainty prior to site mobilization.

SEC 02

Architectural Layout, Structural Grid & Spatial Zoning

Structural Grid & Modular Alignment: Clear-span portal frames (20 m – 60 m), multi-story braced/moment grids, overhead crane girders, and mezzanine decks.

Primary column grids, facade mullion subdivisions, and subterranean parking geometry are locked onto a unified datum—eliminating non-standard off-cuts and costly site framing adjustments.

SEC 03

Functional Area Program & Net-to-Gross Floor Plate Optimization

Spatial Program & Net-to-Gross Efficiency: Tonnage-per-m² optimization balancing standard mill section availability (HEA/HEB/IPE/UB) against fabrication labor hours.

Live parametric Revit area schedules track net usable/leasable floor area against vertical cores, MEP plantrooms, and envelope wall thickness at every design iteration.

SEC 04

Circulation Cores, Logistics Access & Life-Safety Egress

Vertical Cores, Logistics & Life-Safety Egress: Industrial catwalks, caged/spiral maintenance ladders, crane maintenance platforms, and EN ISO 14122 handrails detailed in 3D.

Travel distances, pressurized stair cores, ADA/accessible routing, and heavy service/loading dock swept-path geometry are validated against NFPA, EN, and local building regulations.

SEC 05

Site Utilities, Stormwater Drainage & Wet-Shaft Engineering

Subsurface Utilities, Drainage & Wet Shafts: Pre-engineered cellular/castellated beam web openings reinforced for large process piping and HVAC mains.

Gravity stormwater and foul drainage stacks are modeled with true 1.5%–2.0% invert slopes, locking structural beam web penetrations and acoustic riser sleeves before rebar detailing.

SEC 06

Plumbing, Fire Suppression (NFPA / EN) & Hydronic Piping BIM

Domestic Plumbing, NFPA/EN Sprinkler & Hydronics: Roof purlin and truss node point-load allowances verified for wet/ESFR warehouse sprinkler grids.

Wet/dry sprinkler grids, fire hose cabinets, booster pump skids, and hydronic manifolds are spatially coordinated above ceiling plenums without compromising architectural clear heights.

SEC 07

HVAC Climatic Routing, Acoustic Control & Zero-Clash MEP

HVAC Routing, Acoustics & Zero-Clash Verification: Rooftop packaged unit steel dunnage frames and vibration-isolated equipment platforms coordinated with roof sheeting.

Automated Navisworks and Solibri rule-sets enforce ±3 mm hard-clash tolerances and 25–50 mm insulation/maintenance clearance zones, closing 100% of BCF issues prior to tender issue.

SEC 08

Structural Steel / RC Framing & Seismic Performance Analysis

Structural Framing & Seismic Engineering: Moment end-plates, haunches, gussets, baseplates, shear studs, and cast-in HD holding-down anchor bolt templates calculated and clash-checked.

Inter-story seismic drift ratios, ductile steel moment/braced connections, foundation punching shear, and secondary facade subframes are signed off by our senior structural engineering partners.

SEC 09

Facade Envelope, Roof Assembly & Hygrothermal U-Value Detailing

Building Envelope & Hygrothermal Physics: Cold-formed Z/C secondary purlins, side-rails, sag-rods, and facade curtain-wall cleat plates detailed ready for cladding.

2D/3D thermal-bridge condensation risk is audited per EN ISO 6946, pairing Class A1 mineral-wool insulation, vapor-permeable membranes, and slotted seismic facade brackets at 1:5 shop detail scale.

SEC 10

Georeferenced Site Plan & ISO 19650 Common Data Environment (CDE)

Georeferenced Masterplan & ISO 19650 CDE: IFC4 Structural Analysis & Reference views synchronized continuously with architectural and MEP models.

All discipline models share true survey coordinates (UTM / National Grid) and progress through ISO 19650 WIP → Shared → Published gates inside the Common Data Environment.

SEC 11

BIM & Construction Document Deliverables (.RVT / .IFC4 / .NWD / .DWG)

Native BIM & Construction Documentation Package: 3D Tekla/Revit model, Anchor Bolt Setting Plans, General Arrangement (GA) erection sets, Single-Part & Assembly sheets, .NC1/.DXF files, and Bolt/Paint lists.

Clients receive unlocked native Tekla / Revit .IFC4 · .NC1 (DSTV) · .DXF · GA & Assembly .DWG source files, plotted PDF/DWG construction sets, and signed zero-clash audit certificates.

SEC 12

5D Quantity Take-Off (BoQ), Studio Fee Band & Cost Benchmarks

5D Quantity Take-Off (BoQ) & Indicative Studio Fee: The indicative engineering & BIM fee band for this reference scope is $14,000 – $32,000 (for 10,000 m² / ~450–600t steel ref.) (with indicative construction CAPEX benchmark at Zero Field-Torch Cutting · ±0.5% Steel Tonnage Precision). Optimizes primary steel weight by 6%–12% through refined connection mechanics while preventing crane standby delays on site.

SEC 13

DfMA Prefabrication, 40HC Export Packaging & Execution Pathways

DfMA Prefabrication & Export Execution Pathways: Part lengths and splice locations engineered for 11.85 m 40HC containers or 13.60 m Euro-trailers, plus hot-dip galvanizing bath limits.

Clients may tender the open BIM package to any local contractor or leverage our integrated group factories (SerBuild steel structures, SerMimar İskele EN 12810 scaffolding, SerMimar Şömine hearths, and SerSourcing 40HC consolidation).

SEC 14

International Building Codes, Green Certification & Grant Readiness

International Codes, Sustainability & Compliance: EN 1993 (Eurocode 3), EN 1998 (Eurocode 8), EN 1090-2 EXC2/EXC3, AISC 360/341, and Turkish Steel Code / TBDY 2018.

Structured directly for LEED / BREEAM / RE2020 energy modeling, UK Building Safety Act Golden Thread compliance, Eurocode National Annexes, and institutional lender due diligence.

INTERACTIVE ENGINEERING & FEE ENGINE

BIM, Masterplan & Facade Scope Calculator

EN 1990–1999 Eurocodes · HOAI LP 2–5 · IFC4
m²
500 m² 10,000 m² 25,000 m² 60,000+ m²
Estimated Studio Engineering Fee Band $65,300 – $84,600 (€60,100 – €77,800)
Estimated Engineering Load 950–1210 man-hours
Milestone Delivery Schedule 6–10 weeks
Est. BIM Views & CD Sheets ~90 sheets / models
Indicative Construction CAPEX Ref. $5,800,000 – $9,200,000
Included Native Deliverables
  • LOD 400 Fabrication .RVT/.IFC
  • Facade Thermal & Bracket Calcs
  • 40HC DfMA Assembly & CNC Schedules
  • 5D Master BoQ
Request Detailed Engineering & Cost Study via WhatsApp
CROSS-DISCIPLINE ARCHITECTURE

Explore complementary BIM levels, building typologies, and facade/DfMA specifications.

TECHNICAL & COMMERCIAL Q&A

Frequently Asked Engineering & Commercial Questions

Direct technical answers on deliverables, ISO 19650 workflows, revisions, and fee structures.

Do you engineer the steel connections (bolts/welds/plates) as well as draft the Tekla shop drawings?
Yes. Unlike pure detailing bureaus that require pre-designed sketches for every joint, our structural engineers perform IDEA StatiCa / Eurocode 3 connection calculations alongside LOD 400 detailing.
Do you check hot-dip galvanizing bath dimensions and vent/drain holes in the 3D steel model?
Yes. For galvanized export structures, assembly sizes are capped to standard kettle dimensions (~12.5 m × 1.4 m × 2.6 m) and hollow/end-plate vent holes are automatically placed into CNC files.
Can you detail hybrid precast concrete columns with structural steel roof trusses?
Yes. Heavy industrial and logistics facilities in Türkiye, Europe, and Central Asia frequently use precast RC columns/foundations paired with long-span steel roof trusses—we detail both corbel embeds and steel trusses in one unified model.
How is structural steel detailing priced—per m² or per metric ton?
We offer either fixed lump-sum pricing per m² or per-ton rates (typically $22–$48/ton depending on industrial repeatability vs. complex architectural steelwork).
Can our fabrication plant feed your .NC1 and .DXF outputs straight into Voortman, Ficep, or Vernet machines?
Yes. All DSTV (.NC1) profile data and .DXF plate contours follow standard CNC post-processor conventions with hard-stamp/scribble part marks included.
SECTION 16 · DIRECT ENGINEERING PROPOSAL & WHATSAPP DESK

Request a Scoped BIM, Masterplan or Facade Engineering Proposal

Share your site parcel, CAD sketches, or point-cloud survey directly with our founding architects and civil engineers. Receive an itemized LOD deliverables matrix and fixed milestone schedule within 24 hours.