SerMimar® Studio · Est. 2008 · ISO 19650 BIM & Architectural Engineering
SERMIMAR EST. 2008
Masterplan + LOD 350 BIM 80–150 Units · 14,000 – 28,000 m² GFA

100-Unit Residential Community Masterplan: Efficiency, Parking & Fee Guide

Sellable-area optimization, column-aligned underground parking grids, and phased construction BIM for 80–150 apartment & townhouse estates.

Multi-block 100-unit residential community masterplan with central courtyard and地下 parking alignment
Urban Masterplan + Subterranean Garage + 4-Discipline Block BIM 5 – 8 Weeks
Engineering Specification & Fee Snapshot
ISO 19650 · Eurocode 2/8 · TBDY 2018 · NFPA 101 / EN
BIM Detail Level Masterplan + LOD 350 BIM
Reference Scale 80–150 Units · 14,000 – 28,000 m² GFA
Delivery Schedule 5 – 8 Weeks
Indicative Studio Fee $36,000 – $68,000 (for ~18,000 m² Multi-Block Estate)
Ref. Construction CAPEX $16.5M – $26.0M Indicative Construction Ref.
Native File Outputs Phased Masterplan + Multi-Block 4D/5D BIM + Underground Garage Set
A B C SITE MASTERPLAN & INFRASTRUCTURE ZONING MATRIX ARCHITECTURAL ENVELOPE (U ≤ 0.24 W/m²K) STRUCTURAL FRAME & SEISMIC NODE (EC8 / TBDY) MEP CORRIDOR — ZERO CLASH ZONE (±3 mm) 5D BoQ & CNC / SHOP DRAWING OUTPUT SERMIMAR STUDIO · ISO 19650 · IFC4 / RVT / DWG

Technical Parameters & Tolerance Matrix

Engineering Parameter Specification Benchmark
Target BIM Level & Governing Norm Masterplan + LOD 350 BIM · ISO 19650 · Eurocode 2/8 · TBDY 2018 · NFPA 101 / EN
Reference Gross Scale 80–150 Units · 14,000 – 28,000 m² GFA
Coordinated Disciplines Urban Masterplan + Subterranean Garage + 4-Discipline Block BIM
Milestone Delivery Schedule 5 – 8 Weeks
Indicative Studio Fee Band $36,000 – $68,000 (for ~18,000 m² Multi-Block Estate)
Native File Deliverables Phased Masterplan + Multi-Block 4D/5D BIM + Underground Garage Set
SEC 01

Project & Engineering Scope Overview

In a 100-unit residential development, losing just 3% in net-to-gross corridor efficiency or misaligning apartment shear walls with basement parking bays destroys millions in developer margin. SerMimar engineers parking-first structural grids (7.80 m / 8.10 m) paired with sunlit dual-aspect apartment floor plates.

Engineered to Masterplan + LOD 350 BIM precision across a reference benchmark of 80–150 Units · 14,000 – 28,000 m² GFA under ISO 19650 · Eurocode 2/8 · TBDY 2018 · NFPA 101 / EN, this canonical specification unifies spatial design, multidisciplinary clash resolution, and 5D cost certainty prior to site mobilization.

SEC 02

Architectural Layout, Structural Grid & Spatial Zoning

Structural Grid & Modular Alignment: Strict 7.80 m – 8.10 m structural bay modulation accommodating 3 clean parking stalls per span without costly transfer beams.

Primary column grids, facade mullion subdivisions, and subterranean parking geometry are locked onto a unified datum—eliminating non-standard off-cuts and costly site framing adjustments.

SEC 03

Functional Area Program & Net-to-Gross Floor Plate Optimization

Spatial Program & Net-to-Gross Efficiency: 82%–86% above-grade net-to-gross floor plate efficiency balancing 1+1, 2+1, 3+1, and garden/penthouse duplex unit mixes.

Live parametric Revit area schedules track net usable/leasable floor area against vertical cores, MEP plantrooms, and envelope wall thickness at every design iteration.

SEC 04

Circulation Cores, Logistics Access & Life-Safety Egress

Vertical Cores, Logistics & Life-Safety Egress: Compact dual-core or pressurized scissor-stair vertical cores serving 3–4 apartments per landing with natural daylight.

Travel distances, pressurized stair cores, ADA/accessible routing, and heavy service/loading dock swept-path geometry are validated against NFPA, EN, and local building regulations.

SEC 05

Site Utilities, Stormwater Drainage & Wet-Shaft Engineering

Subsurface Utilities, Drainage & Wet Shafts: Stacked vertical wet-shaft columns aligning kitchens and bathrooms floor-to-floor with zero horizontal slab soffit offsets.

Gravity stormwater and foul drainage stacks are modeled with true 1.5%–2.0% invert slopes, locking structural beam web penetrations and acoustic riser sleeves before rebar detailing.

SEC 06

Plumbing, Fire Suppression (NFPA / EN) & Hydronic Piping BIM

Domestic Plumbing, NFPA/EN Sprinkler & Hydronics: Basement OH2/OH3 sprinkler grids, jet-fan smoke impulse ventilation (CFD-ready), and centralized booster/greywater rooms.

Wet/dry sprinkler grids, fire hose cabinets, booster pump skids, and hydronic manifolds are spatially coordinated above ceiling plenums without compromising architectural clear heights.

SEC 07

HVAC Climatic Routing, Acoustic Control & Zero-Clash MEP

HVAC Routing, Acoustics & Zero-Clash Verification: Basement ramp/drive-aisle headroom ≥2,250 mm guaranteed below jet fans, fire mains, and EV charger busbars.

Automated Navisworks and Solibri rule-sets enforce ±3 mm hard-clash tolerances and 25–50 mm insulation/maintenance clearance zones, closing 100% of BCF issues prior to tender issue.

SEC 08

Structural Steel / RC Framing & Seismic Performance Analysis

Structural Framing & Seismic Engineering: Ductile RC shear-wall/frame superstructure over continuous raft foundation with seismic movement joints between podium and blocks.

Inter-story seismic drift ratios, ductile steel moment/braced connections, foundation punching shear, and secondary facade subframes are signed off by our senior structural engineering partners.

SEC 09

Facade Envelope, Roof Assembly & Hygrothermal U-Value Detailing

Building Envelope & Hygrothermal Physics: High-durability ventilated rainscreen + insulated render envelope with acoustic inter-tenancy party walls (≥56 dB).

2D/3D thermal-bridge condensation risk is audited per EN ISO 6946, pairing Class A1 mineral-wool insulation, vapor-permeable membranes, and slotted seismic facade brackets at 1:5 shop detail scale.

SEC 10

Georeferenced Site Plan & ISO 19650 Common Data Environment (CDE)

Georeferenced Masterplan & ISO 19650 CDE: Linked Revit block instances placed onto a shared georeferenced podium/basement file for instant site-wide schedule updates.

All discipline models share true survey coordinates (UTM / National Grid) and progress through ISO 19650 WIP → Shared → Published gates inside the Common Data Environment.

SEC 11

BIM & Construction Document Deliverables (.RVT / .IFC4 / .NWD / .DWG)

Native BIM & Construction Documentation Package: Site Masterplan, Underground Garage BIM, Typical Block 4-Discipline LOD 350 Models, Unit Sales Area Booklets, and 5D BoQ.

Clients receive unlocked native Phased Masterplan + Multi-Block 4D/5D BIM + Underground Garage Set source files, plotted PDF/DWG construction sets, and signed zero-clash audit certificates.

SEC 12

5D Quantity Take-Off (BoQ), Studio Fee Band & Cost Benchmarks

5D Quantity Take-Off (BoQ) & Indicative Studio Fee: The indicative engineering & BIM fee band for this reference scope is $36,000 – $68,000 (for ~18,000 m² Multi-Block Estate) (with indicative construction CAPEX benchmark at $16.5M – $26.0M Indicative Construction Ref.). Eliminating transfer slabs and cutting gross basement m² per car from 38 m² down to 29–31 m² yields massive foundation savings.

SEC 13

DfMA Prefabrication, 40HC Export Packaging & Execution Pathways

DfMA Prefabrication & Export Execution Pathways: Standardized kitchen/wardrobe joinery modules, pre-hung fire door sets, and facade window sizes across all 100 units.

Clients may tender the open BIM package to any local contractor or leverage our integrated group factories (SerBuild steel structures, SerMimar İskele EN 12810 scaffolding, SerMimar Şömine hearths, and SerSourcing 40HC consolidation).

SEC 14

International Building Codes, Green Certification & Grant Readiness

International Codes, Sustainability & Compliance: Eurocode 2/8, TBDY 2018, acoustic party-wall norms (EN ISO 717), and EV-ready subterranean parking fire regulations.

Structured directly for LEED / BREEAM / RE2020 energy modeling, UK Building Safety Act Golden Thread compliance, Eurocode National Annexes, and institutional lender due diligence.

INTERACTIVE ENGINEERING & FEE ENGINE

BIM, Masterplan & Facade Scope Calculator

EN 1990–1999 Eurocodes · HOAI LP 2–5 · IFC4
m²
500 m² 10,000 m² 25,000 m² 60,000+ m²
Estimated Studio Engineering Fee Band $107,100 – $138,800 (€98,500 – €127,700)
Estimated Engineering Load 1585–2025 man-hours
Milestone Delivery Schedule 10–17 weeks
Est. BIM Views & CD Sheets ~160 sheets / models
Indicative Construction CAPEX Ref. $18,900,000 – $27,900,000
Included Native Deliverables
  • Federated .RVT / .NWD
  • BCF Clash-Free Audit Report
  • 5D Itemized BoQ (.XLSX)
  • Full CD .DWG Set
Request Detailed Engineering & Cost Study via WhatsApp
CROSS-DISCIPLINE ARCHITECTURE

Explore complementary BIM levels, building typologies, and facade/DfMA specifications.

TECHNICAL & COMMERCIAL Q&A

Frequently Asked Engineering & Commercial Questions

Direct technical answers on deliverables, ISO 19650 workflows, revisions, and fee structures.

How do you reduce underground parking construction cost per apartment?
By locking upper-floor apartment shear walls directly onto a 7.80 m or 8.10 m three-car structural grid, we eliminate 1.2 m deep concrete transfer beams and achieve 29–31 m² gross basement area per stall instead of wasteful 38–42 m² layouts.
How are multiple identical or mirrored residential blocks managed in Revit BIM?
Typical block archetypes are authored as clean master Revit models and linked by shared coordinates onto the unified basement/landscape model—ensuring one refinement updates all blocks simultaneously.
Do you engineer acoustic sound insulation between neighboring apartments?
Yes. Party walls and floating screed floors are detailed to ≥55–60 dB airborne and impact sound insulation using twin-stud SerDryWall acoustic assemblies or high-mass SerBims blocks.
Are electric vehicle (EV) charging load capacity and basement smoke extraction included?
Yes. Basement electrical busbars/trays, transformer sizing for EV chargers, and jet-fan smoke clearance heights are fully coordinated in 3D.
Can the 100-unit community be split into two 50-unit construction phases?
Yes. Structural expansion joints and basement utility loops are positioned along phase boundaries so Phase 1 residents move in safely while Phase 2 is built.
SECTION 16 · DIRECT ENGINEERING PROPOSAL & WHATSAPP DESK

Request a Scoped BIM, Masterplan or Facade Engineering Proposal

Share your site parcel, CAD sketches, or point-cloud survey directly with our founding architects and civil engineers. Receive an itemized LOD deliverables matrix and fixed milestone schedule within 24 hours.